SCOPE
Providing engineering services to Amal for revamping of their SA Plants to a capacity of 140 TPD on a consistent basis with following product mix:
- Liquid SO3 58 TPD
- 25% Oleum 10 TPD
- Liquid SO2 12 TPD
- 98% Sulphuric Acid balance and to be minimized
Based upon data collected a study has been done and some equipment have been identified to be replaced or modified. There are some equipment which will be retained as it is. This document describes all such equipment.
- Sulphur Furnace
- Hot Gas By Pass Valve
- Sulphur Gun
- Fuel Oil Burner Unit
- Economizer -1
- Economizer -2
- Waste Heat Boiler
- Demister pad for 25% oleum tower
- Quench Air Mist Eliminator
- Converter
- Hot Heat Exchanger
- Superheater
- Boiler Feed Water Pump